This course will cover the RTHA, RTHB, RTHC, RTHD, RTWA (water-cooled screw chillers) and the RTAA, RTAC (air-cooled screw chiller). The seminar will cover the normal operation of this equipment.

Speaker System Tuner Turn-Table: laptop. 2014 Subaru Forester 2.5i Touring Owners & Navigation Manual. Total Pages in Manual. 2014 subaru forester navigation system manual. Download manual 2014 Subaru Forester Manual Description Read this manual carefully before using navigation, resulting from failure to follow instructions, follow all road signs traffic rules, when driving using guidance navigation system. View and Download Subaru Forester 2014 quick reference manual online. Forester 2014 Automobile pdf manual. For Navigation System.” 1353095_14a_Subaru. Read this manual carefully before using navigation, resulting from failure to follow instructions, follow all road signs traffic rules, when driving using guidance navigation system, be sure to follow the actual road signs traffic. View and Download Subaru Navigation System 2014 BRZ quick reference manual online. Navigation System 2014 BRZ Car Navigation system pdf manual download. Also for: Navigation system 2014 forester, Navigation system 2014 impreza, Navigation system 2014 wrx, Navigation system 2014 sti.

  1. Trane Chiller Manuals
  2. Trane Chiller Manual 450

View and Download Trane RTHD user manual online. Series R Helical Rotary Liquid Chillers. RTHD Chiller pdf manual download. I have a trane chiller model # CVHE500 that has a problem with surging after initial startup. When I switch over to this chiller, as soon as the vanes start opening the chiller starts surging very loudly.

These two types of chillers have completely different control panels and sequences of operation, both of which will be covered in depth, along with reports, programming, and troubleshooting. Also, startup and shutdown procedures and preventive maintenance items will be covered. We will also discuss how to log these chillers and get the information needed to maintain efficient operating machines. A section will be devoted to refrigerant management and conservation procedures, including transferring or recovery of high-pressure refrigerants. Audience: This class is intended for building operators, facility personnel, and property managers. Tuition: $450 per student (includes breakfast and lunch, and all training materials) Discount: $50 discount for each additional student from the same company (only applies to same class, same company).

Summary of Contents of user manual for Trane RTAC 140-500 ton units (60 Hz). Installation Operation Preliminary Maintenance Series R Air-Cooled Helical Rotary Liquid Chillers Models RTAC 140-500 ton units (60 Hz) RTAC. NOTICE: Warnings and Cautions appear at appropriate sections through- out this literature. Read these carefully.  WARNING: Indicates a.

Table of Contents General Information. 7 Literature History. 7 Unit Identification - Nameplates. 7 Unit Inspection. Table of Contents Leak Test and Evacuation. 58 Refrigerant and Additional Oil Charge. 60 Refrigerant Charge Determination.

Trane Chiller Manuals 450

Table of Contents Modes Screen. 95 Chiller Screen. 101 Compressor Screen. 101 Refrigerant Screen. 102 Setpoint. Table of Contents Periodic Maintenance.

149 Weekly Maintenance. 149 Maintenance Procedures. 155 Refrigerant and Oil Charge Management. General Information Literature History RTAC-SVX001-EN (December 2000) New manual.

RTAC-SVX01B-EN (September 2001) New manual describes installation, operation, and maintenance. General information Unit Inspection When the unit is delivered, verify that it is the correct unit and that it. General Information. Figure 2 Typical RTAC Unit Chilled water inlet and outlet openings are covered for shipment. General information Table 1 General Data — 140-250 Ton 60 Hz Units - Standard Efficiency Size 140 155 170. General Information Table 2 General Data — 275- 500 Ton 60 Hz Units - Standard Efficiency Size 275 300.

General information Table 3 General Data — 140-400 Ton 60 Hz Units - High Efficiency Size 140 155 170. General Information Table 4 General Data - 120-400 Ton 50 Hz Units-Standard Efficiency Size 140 155 170 185 200. General information Table 5 General Data - 120-400 Ton 50 Hz Units-High Efficiency Size 140 155 170 185 200. General Information Figure 3 Unit Dimensions 185-200 Ton Standard Efficiency, 60 Hz and 155, 170 Ton, High Efficiency, 50. Figure 4 Unit Dimensions 225-250 Ton Standard Efficiency, 60 Hz and 185-200 Ton, High Efficiency, 50 and 60 Hz 16. Figure 5 Unit Dimensions 225-250 Ton High Efficiency, 60 Hz RTAC-SVX01F-EN 17. Figure 6 Unit Dimensions 250-275 Ton Standard Efficiency, 50 Hz and 250 Ton High Efficiency, 50 Hz and 275 Ton.

Figure 7 Unit Dimensions 275 Ton High Efficiency, 50 and 60 Hz; 300 Ton, Standard Efficiency, 50 and 60 Hz. Figure 8 Unit Dimensions 300 Ton High Efficiency, 50 and 60 Hz 20 RTAC-SVX01F-EN.

Figure 9 Unit Dimensions 350-400 Ton Standard Efficiency, Hz and 400 Ton, Standard Efficiency, 60 Hz and 350 Ton High. Figure 10 Unit Dimensions 450-500 Ton Standard Efficiency, 60 Hz and 375-400 Ton, High Efficiency, 50 Hz and 400 Ton. Figure 11 Unit Dimensions of Condenser/Compressor Unit for Remote Evaporator Option RTAC-SVX01F-EN 23.

Figure 12 Unit Dimensions for Remote Evaporator 140-170 Ton Standard Efficiency and 140 Ton High Efficiency 24 RTAC-SVX01F-EN. Figure 13 Unit Dimensions for Remote Evaporator185-250 Ton Standard Efficiency and 155-200 Ton High Efficiency RTAC-SVX01F-EN 25. Model Number Coding System The model numbers for the unit and the starter are composed of numbers and letters. Digit 1-4 Digit 17 Digit 27 Unit Model Condenser Temperature Range Short Circuit Rating RTAC Air Cooled Series R®. Installation - Mechanical Installation Responsibilities Generally, the contractor must do the following when installing an RTAC unit:. Install. Installation - Mechanical Storage Extended storage of the outdoor unit prior to installation requires the following pre- cautionary measures.

Installation - Mechanical 1. Lifting chains/cables will not be the same length. Adjust to keep unit level while lifting. Installation - Mechanical: Table 6 Lifting Weights and CG Dimensions (Refer to Figure 14 - Figure 15) W1. Installation - Mechanical Table 6 Lifting Weights and CG Dimensions (Refer to Figure 14 - Figure 15) W1 W2. Installation - Mechanical Table 6 Lifting Weights and CG Dimensions (Refer to Figure 14 - Figure 15) W1 W2.

Installation - Mechanical Table 6 Lifting Weights and CG Dimensions (Refer to Figure 14 - Figure 15) W1 W2. Installation - Mechanical Table 6 Lifting Weights and CG Dimensions (Refer to Figure 14 - Figure 15) W1 W2. Installation - Mechanical Table 6 Lifting Weights and CG Dimensions (Refer to Figure 14 - Figure 15) W1 W2.

Installation - Mechanical Table 8 Unit Isolators Tonnage Efficiency Frequency Unit Type Condenser Isolator Part Quantity Fin Material Number. Installation - Mechanical Foundation Provide rigid, non-warping mounting pads or a concrete foundation of sufficient strength and mass to.

Installation - Mechanical Figure 19 Recommended Unit Clearances 18-21 foot bases Figure 20 Recommended Unit Clearances 30-45 foot bases. Installation - Mechanical Figure 21 Recommended Remote Evaporator Unit Clearances 15-30 foot bases Figure 22 Recommended Evaporator Clearance Unobstructed. Installation - Mechanical Debris, trash, supplies etc. Should not be allowed to accumulate in the vicinity of the unit. Installation - Mechanical Provide shutoff valves in lines to the gauges to isolate them from the system when they. Installation - Mechanical 2.

To prevent switch fluttering, remove all air from the water system. NOTE: The CH530 provides. Installation - Mechanical Evaporator Water Pressure Drop RTAC 250 - 500 Ton Water-Side Pressure Drop vs Flow Rate 100.0. Installation - Mechanical Neither salt nor brackish water is recommended for use in Trane air-cooled Series R® chillers. Installation - Mechanical Water Pressure Relief Valves CAUTION Shell Damage! To prevent shell damage, install pressure relief valves in.

Installation - Mechanical Important 1. Additional glycol beyond the recommendations will adversely effect unit perfor- mance. The unit efficiency. Installation - Mechanical Table 9 Glycol Recommendations Ethylene Glycol Propylene Glycol DT 4 6 8 10 12 14 16. Installation - Mechanical Remote Evaporator Option The RTAC 140-250 ton outdoor unit with the Remote Evaporator option is shipped. Installation - Mechanical Remote Evaporator Option 7.

Figure 26, drawing 1 depicts an installation where the remote evaporator eleva. Installation - Mechanical Remote Evaporator Option Figure 26 Remote Evaporator Installations RTAC-SVX01F-EN 51.

Installation - Mechanical Remote Evaporator Option Figure 27 Circuit Identification 52 RTAC-SVX01F-EN. Installation - Mechanical Remote Evaporator Option R TAC 140-250 To n R em o te E vap o rato. Installation - Mechanical Remote Evaporator Option Table 12 Equivalent Lengths of Non-Ferrous Valves and Fittings (feet) Line Size Inches. Installation - Mechanical Remote Evaporator Option Required Length in Feet of Field Installed Suction Line Accumulator 70 Ton Circuit. Installation - Mechanical Remote Evaporator Option For this example, refer to Table 11, Table 12 and Figure 28. Installation - Mechanical Remote Evaporator Option Suction Accumulator Sizing Use Table 13 to calculate length and size of the. Installation - Mechanical Remote Evaporator Option Refrigerant Sensors All necessary refrigerant devices, transducers and solenoids are factory installed and.

Installation - Mechanical Remote Evaporator Option  WARNING Hazard of Explosion! Use only dry nitrogen with a pressure regulator. Installation - Mechanical Remote Evaporator Option Figure 30 Field Wiring between Remote Evaporator and Condensing Unit Refrigerant and Additional. Installation - Mechanical Remote Evaporator Option 1.

To determine the appropriate charge, first refer to the General Data Tables. Installation - Electrical General Recommendations All wiring must comply with local codes and the National Electric Code. Typical field. Installation - Electrical Table 17 Unit Electrical Data for Std. Efficiency at All Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 17 Unit Electrical Data for Std. Efficiency at All Ambient Operation Unit Wiring Motor Data.

Installation - Electrical Table 17 Unit Electrical Data for Std. Efficiency at All Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 17 Unit Electrical Data for Std.

Efficiency at All Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 18 Unit Electrical Data for High Efficiency at Std. Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 18 Unit Electrical Data for High Efficiency at Std.

Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 18 Unit Electrical Data for High Efficiency at Std. Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 18 Unit Electrical Data for High Efficiency at Std. Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 19 Unit Electrical Data for High Efficiency at High Ambient Operation Unit Wiring Motor Data.

Installation - Electrical Table 19 Unit Electrical Data for High Efficiency at High Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 19 Unit Electrical Data for High Efficiency at High Ambient Operation Unit Wiring Motor Data. Installation - Electrical Table 19 Unit Electrical Data for High Efficiency at High Ambient Operation Unit Wiring Motor Data. Installation - Electrical Installer-Supplied Components Customer wiring interface connections are shown in the electrical schematics and connection diagrams that. Installation - Electrical 115 volt field-provided connections (either control or power) are made through knockouts on the lower left.

Trane Chiller Manuals

Installation - Electrical CAUTION Heat Tape! Control panel main processor does not check for loss of power to the. Installation - Electrical Table 20 Pump Relay Operation Chiller Mode Relay Operation Auto Instant close Ice Building Instant close. Installation - Electrical Table 21 Alarm and Status Relay Output Configuration Table Description Alarm Ckt 1 This output is.

Installation - Electrical Silver or gold-plated contacts are recommended. These customer-furnished contacts must be compatible with 24 VDC, 12. Installation - Electrical permit the ice building mode to be reentered until the unit has been switched out of.

Installation - Electrical If the ECLS input develops an open or short, the LLID will report either a very. Installation - Electrical. Start Reset Set Points. Maximum Reset Set Points. The equations for each type of. Installation - Electrical When the chiller is not running the CWS is reset immediately (within one minute) for Return.

Installation - Electrical Table 24 LonTalk Points List LonTalk Communications Interface Inputs Variable type SNVTType Chiller Enable/Disable binary start(1)/stop(0). Operating Principles This section contains an overview of the operation and maintenance of RTAC units equipped with CH530 control. Operating Principles Figure 34 System Schematic RTAC-SVX01F-EN 87. Operating Principles Refrigerant R134a The RTAC chiller uses environmentally friendly R134a. Trane believes that responsible refrigerant practices are important. Operating Principles some fans are shut off to maintain the pressure differential.

Fan staging depends on the chiller load. Operating Principles Oil that gets past the oil separators flows through the condenser, subcooler and expansion valve into the. Controls Interface CH530 Communications Overview The Trane CH530 control system that runs the chiller consists of several elements:. Controls Interface Figure 36 DynaView Key Functions In this touch screen application, key functions are determined completely by software.

Manuals

Controls Interface its tab, thereby making it look like a part of the current folder (as would an open. Controls Interface The ALARMS button appears only when an alarm is present, and blinks (by alternating between normal and. Controls Interface If the Display and Touch Screen Lock feature is disabled, the following screen is auto- matically displayed. Controls Interface Table 25 Chiller Modes Chiller Modes Description Top Level Mode Sub-modes Stopped The chiller is not running. Controls Interface Table 25 Chiller Modes Chiller Modes Description Top Level Mode Sub-modes Start Inhibited by BAS The chiller.

Controls Interface Table 25 Chiller Modes Chiller Modes Description Top Level Mode Sub-modes Unit is Building Ice The chiller. Controls Interface Table 26 Circuit Modes Circuit Modes Description Top Level Mode Sub-modes Auto The given circuit is not. Controls Interface Table 27 Compressor Modes Compressor Modes Description Top Level Mode Sub-modes Stopped The given compressor is not. Controls Interface Table 27 Compressor Modes Compressor Modes Description Top Level Mode Sub-modes Diagnostic Shutdown - Auto Reset The. Controls Interface Each compressor has its own screen depending on which radio key is pressed. When toggling between compressor. Controls Interface Table 30 Refrigerant Screen Description Resolution Units Cond Rfgt Pressure Ckt1/Ckt2 X.X Pressure Sat Cond Rfgt Temp.

Trane Chiller Manual 450

Controls Interface Table 31 Setpoint Screen Description Resolution or Text Units Comp 1A Pumpdown Pumpdown/Abort Text Comp 1B Pumpdown. Controls Interface tics, consistent with the circuit to which they belong. One circuit not operating will not shut the.

TechView Figure 37 TechView TechView is the PC (laptop) based tool used for servicing Tracer CH530. Technicians that make. TechView Minimum PC requirements to install and operate TechView. Pentium II or higher processor. 128Mb RAM.

TechView Upon successful Local Connect Tech View will display UNIT VIEW. RTAC Unit View is shown below Figure 38. TechView Compressor Service View The Compressor View provides convenient access to service functions for pumping down circuits and test. TechView Status View Status View displays, in real time, all non-setpoint data organized by subsystem tabs. As data changes.

TechView Table 34 Status View Items Tab Text Units Chiller Chiller Top Level Operating Mode Text Chiller Sub Operating. TechView Table 34 Status View Items Tab Text Units Compressor Line 3 Current% RLA Maximum Line Current Amps. TechView Setpoint View Setpoint view displays the active setpoints and allows you to make changes. Figure 41 Setpoint View.

TechView Setpoint Numeric Panel A setpoint numeric panel contains a label with the setpoint description, a Default button, a. TechView Table 35 Setpoints View Items Min Max Default Tab Text Value Value Value Unit Type Chiller Front Panel.

TechView Table 35 Setpoints View Items Min Max Default Tab Text Value Value Value Unit Type Chiller Outdoor Maximum. TechView Diagnostics View This window lists the active and inactive (history) diagnostics. There can be up to 60 diagnostics. TechView Configuration View This view displays the active configuration and allows you to make changes. Figure 43 Configuration View. TechView Selecting the Undo All button will undo any configuration setting changes made during the present TechView connection and. TechView Table 36 Configuration View Items Tab Item Default Description Feature Condenser Fan/Motor Configuration N - Condenser fans with.

TechView Table 36 Configuration View Items Tab Item Default Description Features Installation Accessories N - No installation accessories R. TechView Software View Software view allows you to verify the version of chiller software currently running on the EasyView. TechView Binding View Binding View allows you to assess the status of the network and all the devices connected.

TechView Replacing or Adding Devices If a device is communicating but incorrectly configured, it might not be necessary to. TechView 5. Proceed to “Main Processor Software Download” page and read the instructions to download the latest version of. Diagnostics The following Diagnostic Table contains all diagnostics possible arranged alphabetically by the name assigned to each diagnostic. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level 69F Comm Loss: Evap Oil Return. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level 698 Comm Loss: Fan Inverter Normal.

Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level 5E2 Comm Loss: Outdoor Air Normal. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level 6B9 Evaporator Rfgt Drain - NA. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level BE High Pressure Cutout - Immediate. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level B5 Low Suction Refrigerant Immediate Latch. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level 19D Phase Loss - Compressor 1B.

Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level CC Starter Contactor Interrupt Special Latch. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level 5C8 Starter Module Memory Error Info. Diagnostics Hex Diagnostic Name Severity Persis- Criteria Reset Code and Source tence Level D8 Under Voltage Normal NonLatch a. Pre-Start Checkout Installation Checklist Complete this checklist as the unit is installed and verify that all recommended proce- dures. Pre-Start Checkout Electrical Wiring  WARNING Hazardous Voltage w/Capacitors!

Disconnect all electric power, including remote disconnects before servicing. Pre-Start Checkout. If alarm and status relay outputs are used, install leads from the panel to the proper. Pre-Start Checkout CAUTION Compressor Damage! It is imperative that L1, L2, L3 in the starter be connected in the. Pre-Start Checkout CAUTION Equipment Damage!

Provide adequate voltage to the unit. Failure to do so can cause control components. Pre-Start Checkout  WARNING Hazardous Voltage w/Capacitors! Disconnect all electric power, including remote disconnects before servicing.

Follow proper lockout/tagout. Pre-Start Checkout CH530 Set-Up Use of TechView service tool is required to view and adjust most settings. Unit Start-Up Procedures Daily Unit Start-Up The time line for sequence of operation is shown at the end of. Unit Start-Up Procedures Once the system has been operating for approximately 30 minutes and has become stabilized, complete the.

Unit Start-Up Procedures System Restart After Extended Shutdown Follow the procedures below to restart the unit after extended shutdown. Unit Shutdown Procedures Temporary Shutdown And Restart To shut the unit down for a short time, use the following.

Unit Shutdown Procedure CAUTION Disconnect Power! Lock the disconnects in the “OPEN” position to prevent accidental start- up and. Periodic Maintenance Perform all maintenance procedures and inspections at the recommended intervals. This will prolong the life of the. Periodic Maintenance  WARNING Hazardous Voltage w/Capacitors!

Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout. Periodic Maintenance RTAC Start-up Test Log Job Name Job Location Model # CRC # Serial # Sales Order #. Periodic Maintenance RTAC Unit Configuration Job Name Job Location Model # Serial # CRC# Sales Order # Ship Date. Periodic Maintenance RTAC Chiller Log Job Name Job Location Model # Serial # Status View:. Chiller Tab: 15. Periodic Maintenance Compressor 2A Tab Compressor 2B Tab Operating Mode Hours Hrs/mins Hrs/mins Starts 15 min 30 min 45.

Maintenance Procedures Refrigerant and Oil Charge Management Proper oil and refrigerant charge is essential for proper unit operation, unit. Maintenance Procedures. Low oil sump level after normal shut down. Lower than normal oil concentrations in evaporator. Maintenance Procedures 2. Attach charging hose to evaporator service valve (3/8” (9mm) flare). Open service valve.

Maintenance Procedures Table 37 Charge Holding Capabilities on High Side Nominal Circuit Nominal Circuit Condenser Charge Charge in Oil. Maintenance Procedures The evaporator is large enough to hold all the charge for any unit to below the center.

Maintenance Procedures oil will result in high oil circulation rates which will foul the condenser and evaporator performance. Maintenance Procedures Table 38 Oil Charging Data Circuit Approximate sump oil level after Normal quantity of oil in refrigera. Maintenance Procedures CAUTION Equipment Damage! Use only Trane OIL00048 in the RTAC units to avoid any catastrophic damage to. Maintenance Procedures 7.

When oil comes out of the flare fitting on the oil line shut off valve the. Maintenance Procedures 2. Disconnect power to the chiller. Remove the electrical junction box cover and disconnect the wires. Unit Wiring This section provides field wiring diagrams, electrical schematics and connection dia- grams for 140-500 ton RTAC units.