This guide requires a little knowledge of how heaters works. Basic tools and mechanical knowledge along with standard safety protocols should be used.

Be very careful when dealing with Propane as it highly combustable. Also ignitor wire caries an extremely high voltage and should be treated with caution.

Here is what I told one customer: Hi, I noticed your auction for the circuit board for an older Hydroflame furnace. Last week I started mine and it came on for about 5 minutes and then shut off, I waited about 10 minutes and started it again just fine but 5 minutes later it shut off again and now it will not do anything.

I have checked fuses and checked that the 12 volts is getting to it. Is there any way I can check to find out what needs replacing Here is what I wrote him Check to make sure there are no external air leaks into combustion chamber causing your unit to run lean and that inlet and outlet are not blocked modified or obstructed as this will change fuel mixture. If all of these criteria have been met check the flame to see if it is yellow or blue. It should be blue. If it is yellow you have an air intake restriction if blue proceed to pulling out igniter and inspect to make sure the tips are not corroded or melted or possibly bent due to long heat exposure.

Beginning in 2017 Atwood is sold under the Dometic brand. Air Conditioners - Overview RV Air Conditioner Buying Guide Air Conditioners - Overview Air.

8500

You can sand the igniter with 2000 grit sand paper and re-insert it. Check to make sure blower speed is adequate and motor is getting at least 12 Volts.

If error speed is to slow excessive heat will build up and trigger high limit switch to activate. You may also have a fault high limit switch you can check this by attaching a test light to the output soda of the high limit switch wire which we be the white wire on a hydroflame. If light goes off you know the high limit switch triggered occurrence.

Hydro Flame Furnace Excalibur 8500 Ii Manual

Test the input side of the limit switch to verify the light is on. If it is on and you are getting good fan speed meaning a lot of airflow then suspect that the high limit switch is bad and replace it.

If possible measure temp with a infrared temp gun to insure it is prematurely activating. Temp is marked on the HL. If the HLS is good and still doesnt go out I suspect the board could possibly be failing. If that is the case next step would be to test the board. Verify that you are getting power to the board when it shuts down.

Check to see if board off shuts of gas valve. If there is power but shuts off gas valve suspect the sense probe wire or the board is malfunctioning.

Also, there is also a sail switch that allows voltage to the board after the motor on the blower spins creating wind. This should be an in and out wire on the heater. Sequence is power on, power applied to blower, power passes through sail switch if blower is on, then power passes through HLS If cool enough normally closed, then gas valve is opened. Good luck troubleshooting your heater.

Einstiens RV Parts and Electronics. Saint francis prep lab manual.

Atwood Hydroflame RV Furnaces and Heaters for the win Looking for the RV furnace that’s going to really heat things up? Atwood Furnaces are pretty hot right now. For a powerful RV heater that brings the warmth into your living space and the energy efficiency you need from your RV equipment, let Atwood be your man. Easy installation and many years of reliable heat for your mobilehome make Atwood Furnaces one of the best choices on the market.

Don’t be left out in the cold, make sure you have the heat you need to keep those bodies warm and those faces smiling on your next family vacation. Things get hotter with the right RV Furnace Choose from a variety of sizes and BTUs with Atwood Hydroflame Furnaces and Heaters here at PPL Motorhomes’ comprehensive website. We offer the most popular and top selling products on the RV market for over 40 years, with friendly and knowledgeable service and competitive prices, there’s not much we can’t do for you!

Pick up an Atwood Furnace Ignition Adapter Universal DSI board, Hydroflame Motor, or furnace slide out gas valve to get your RV furnace working just right for you. We carry it all! Keep your Atwood Furnace running smoothly Need a quick fix? Atwood Hydro Flame Furnace Motor Kit can give you the convenience of furnace repair and upgrade in your own hands. Save valuable time and money with quality RV equipment and accessories that will bring you reliability and durability long term. Your family vacation should be the only focus you have, and the fun you can have on that RV roadtrip making new memories. At PPL Motorhomes we aim to make your shopping experience an excellent one, let us do the work for you.

Hydro Flame Furnace Excalibur 8500

Tell us how we can help you today!